Release 10.1A: OpenEdge Deployment:
Startup Command and Parameter Reference


After-image Buffers (-aibufs)

Use After-image Buffers (-aibufs) to specify the number of after-image buffers.

Operating system
and syntax
UNIX
Windows
-aibufs n
Use
with
Maximum value
Minimum value
Single-user default
Multi-user default
Database Server
1
20

n

The number of after-image buffers to use.

This parameter is useful only when running the after-image writer (AIW) because the AIW writes the filled After-image Buffers to disk, making the buffers available to other client and server processes. Progress Software Coporation recommends you set After-image Buffers (-aibufs) to the same value specified for the Before-image Buffers (-bibufs) parameter, or a minimum of 20.

Without the AIW writing the buffers, any gain from increasing the number of buffers is negligible.


Copyright © 2005 Progress Software Corporation
www.progress.com
Voice: (781) 280-4000
Fax: (781) 280-4095